5.3 Blade and Virtual Connect Configuration
All the blades are using logical Serial Numbers, MAC addresses and FC WWNs. A single
10Gb network and two 8 Gb FC connections are presented to each host.
Appendix A.6 has complete details of the blade and virtual connection configuration.
5.4 Storage Configuration
Hardware Specifications
1 x HP StorageWorks MSA2324fc
Fibre Channel Storage Array +
HP StorageWorks 70 Modular Smart
Array with Dual Domain IO Module
[total 49 x 146GB 10K RPM SAS disks]
Storage Controller:
Code Version: M110R28
Loader Code Version: 19.009
Memory Controller:
Code Version: F300R22
Management Controller
Code Version: W441R13
Loader Code Version: 12.015
Expander Controller:
Code Version: 1106
CPLD Code Version: 8
Hardware Version: 56
1 x HP StorageWorks 4/16 SAN Switch Firmware: v6.2.2c
1 x HP StorageWorks 8/40 SAN Switch Firmware: v6.4.0a
Table 3: Storage Hardware
The MSA2324fc array was configured with four 11-disk RAID6 vdisks, with online
replacement spares.