Red Hat LC2000r - NetServer - 128 MB RAM Manual de servicio

Busca en linea o descarga Manual de servicio para Los componentes del chasis Red Hat LC2000r - NetServer - 128 MB RAM. Red Hat LC2000r - NetServer - 128 MB RAM Service manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 107
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - Service Manual

HP NetServer LC 2000 Service Manual Online Version: 2.0 Last Updated: April 2000

Pagina 2 - Audience Assumptions

Chapter 1 General Information 4 Always disconnect the power cord before removing any covers, to avoid exposure to high energy levels that may cause

Pagina 3 - Contents

Chapter 6 Replacing Parts 94 CaptiveScrewLocationsCaptiveScrewLocationsRear of System Captive Screw Locations 11. Slide the system board towards t

Pagina 4

Chapter 6 Replacing Parts 95 Replacing the System Board NOTE Verify the switch settings on the defective system board removed are duplicated on the

Pagina 5

Chapter 6 Replacing Parts 96 Processor CageCover Opening the Processor Card Cage 7. Depress the latches at the corners of the terminator card to

Pagina 6

Chapter 6 Replacing Parts 97 Replacing VRMs You may choose to swap out a VRM (voltage regulator module) in the process of troubleshooting processor p

Pagina 7 - 1 General Information

Chapter 6 Replacing Parts 98 Rotate latches out VRM Removal Replacing the VRM 1. Align the replacement VRM over the socket and gently press down.

Pagina 8 - Thumbscrews (2)

99 Index 1 10/100 BaseT Ethernet, 9 2 256 Colors, 17 A AC Input Power, 15 AC power problems, 52 Acoustic Emissions, 16 administrator password, 44 Alt

Pagina 9

Index 100 K keyboard dimensions, 16 problems, 50 Keyboard, 9 keyboard button, 7 L LAN Connector, 14 LC2000 BIOS Update diskette, 42 light pipes, 79 Li

Pagina 10 - Foot Extended

Index 101 Serial A, 9 serial port connector, 9 Serial Port Connector, 12 Setup Utility, 11 SGRAM, 17 single-bit errors, 47 Sound Level, 16 Space Requ

Pagina 11 - Hinge Pins(3) Handles(2)

Chapter 1 General Information 5 Press down onBlue Tab to Release BezelSlide Securing Screws (2)Blue SlideRelease Button (2)Hinge Pins (3) Removing th

Pagina 12 - Cover Pull

Chapter 1 General Information 6 Extending the HP NetServer LC 2000r CAUTION To prevent damage to the covers, support the cover as you remove it fr

Pagina 13 - Lights and Indicators

Chapter 1 General Information 7 The bottom cover does not provide any additional access to the interior, except the bottom of the mass storage drives

Pagina 14 - Communication Ports

Chapter 1 General Information 8 CoverClosedPowerLED HP NetServer LC 2000r (front view) Rear Panel Communication PortsAC PowerInletsPowerSupply #1Red

Pagina 15

Chapter 1 General Information 9 Keyboard MouseVideo NIC(Embedded)Serial ManagementExternal SCSI(Optional)Parallel(printer) Rear Panel Ports l

Pagina 17 - 2 System Information

11 2 System Information Boot Drive Priority The on-board SCSI controller has two channels, A and B. Channel A is typically used to control the Hot Sw

Pagina 18 - Connector Pinouts

Chapter 2 System Information 12 Connector Pinouts Video Connector Pinouts The built-in video uses the standard 15-pin analog display pinout configu

Pagina 19 - Mini-DIN Connectors

Chapter 2 System Information 13 Parallel Port Connector 12345678910111213141516171819202122232425 Pin Number Signal Description Pin Number Signal

Pagina 20 - Technical Specification

ii Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to

Pagina 21 - Environmental Requirements

Chapter 2 System Information 14 LAN Connector 18 Pin Number Signal Description 1 Transmit + 2 Transmit - 3 Receive + 4 Common Mode Termination

Pagina 22

Chapter 2 System Information 15 HP NetServer LC 2000/2000r Power Ratings AC Input Voltages Maximum Input Power (VA) Maximum Input Power (W) Maximum

Pagina 23 - Physical Requirements

Chapter 2 System Information 16 Operating: -30 to 3,045 m (10,000 ft) Non-operating: -30 to 12,180 m (40,000 ft)

Pagina 24 - Switch Settings

Chapter 2 System Information 17 Acoustic Emissions Sound Level: (LpA) < 50 dB(A) bystander position Physical Requirements LC 2000r Weight and Di

Pagina 25 - System Board Illustrations

Chapter 2 System Information 18 Windows NT 4.0 Yes Provided with NOS NetWare 5 No No Driver is available SCO OpenServer 5.0 Yes SCO UnixWare 7

Pagina 26

Chapter 2 System Information 19 Shaded rectanglerepresents theposition of slideswitch.2 Processor Speed (Bit 1)3 Processor Speed (Bit 2)4

Pagina 27

Chapter 2 System Information 20 FlexibleDiskDriveSCSI ASCSI BIDECD-ROM123456Slots P1-432-bit33 MHzSlots P5-664-bit33 MHzControl Panel ConnnectorCon

Pagina 28

Chapter 2 System Information 21 123456Primary ProcessorThermalSensor Location0123SystemBoardThermalSensor LocationSecondaryProcessorThermalSensorLoc

Pagina 30 - Replaceable Parts List

23 3 Parts Information Covers, Fans, Power Supply Exploded View 12352768491010 System Board Exploded View

Pagina 31 - Chapter3 Parts Information

iii Contents 1 General Information ...

Pagina 32 - Chapter 3 Parts Information

Chapter 3 Parts Information 24 16171112141315 Mass Storage Exploded View 2021191822623A, BCD242527262827A Replaceable Parts List

Pagina 33 - 4 Diagnostics

Chapter3 Parts Information 25 NOTE The part numbers listed below were available at the time of publication. Part numbers may change after publicati

Pagina 34 - DiagTools Capabilities

Chapter 3 Parts Information 26 Item Description Replacement Exchange 22 Drive bay cover D8520-63025 23 1.44 MB Floppy Disk Drive D2035-60282

Pagina 35 - POST Routines

27 4 Diagnostics Diagnostics The NetServer is supported by two types of diagnostics: • Boot Diagnostics These are routines that execute automatically

Pagina 36 - Chapter 4 Diagnostics

Chapter 4 Diagnostics 28 Use this topic to learn about how to use HP's NetServer DiagTools. The purpose of hardware diagnostic software is to pr

Pagina 37 - Beep Codes

Chapter 4 Diagnostics 29 • add comments to the Support Ticket If you have TopTools remote management software installed and configured for use with

Pagina 38 - Error Messages

Chapter 4 Diagnostics 30 System (BIOS) ROM Test BIOS ROM chip calculates an eight-bit checksum. Test failure causes an error code to be displayed an

Pagina 39

Chapter 4 Diagnostics 31 Real-Time Clock Test Checks the real-time clock registers and performs a test to ensure the clock is running. Test failure

Pagina 40

Chapter 4 Diagnostics 32 1-3-4-3 Test 64K base memory 2E M, P 1-4-1-1 Test 64K base memory (upper 16 bits) 30 M, P 2-1-2-3 Copyright checksum

Pagina 41

Chapter 4 Diagnostics 33 0011 Battery problem The NetServer BIOS is not responding due to a possible battery discharge. If the HP NetServer was unplu

Pagina 42

iv The System Will Not Power Up...43 The System Will Not B

Pagina 43

Chapter 4 Diagnostics 34 3. Run the Plug & Play utility supported by your Operating System. 4. If the problem persists, the accessory board

Pagina 44

Chapter 4 Diagnostics 35 2. If the error persists, your system board may need to be replaced. Contact your service representative. 0103 Keyboard

Pagina 45

Chapter 4 Diagnostics 36 0201 Parallel Port Controller resource conflict POST has detected an address space or IRQ resource conflict between the int

Pagina 46

Chapter 4 Diagnostics 37 replaced. Contact your service representative. 0307 Flexible disk drive controller resource conflict POST has detected an a

Pagina 47

Chapter 4 Diagnostics 38 Setup. 2. If the IDE device operates with the secondary channel, your system board may need to be replaced to recover pri

Pagina 48

Chapter 4 Diagnostics 39 message applies only to the IDE cable (primary channel) marked IDE cable <#0530>. The secondary channel cable marked

Pagina 49 - 5 Troubleshooting

Chapter 4 Diagnostics 40 To correct this: 1. If additional memory was just installed in your NetServer, please verify the installation conforms to

Pagina 50 - Troubleshooting Checklist

Chapter 4 Diagnostics 41 6. If the error persists, the system board may need to be replaced. Contact your service representative. 0901 Integrated

Pagina 52 - Chapter 5 Troubleshooting

43 5 Troubleshooting Preventive Maintenance Procedures Refer to this table for HP NetServer preventive maintenance procedures. Be sure to turn off t

Pagina 53 - BIOS Recovery

v Replacing a Power Supply ...89 Power Supply R

Pagina 54

Chapter 5 Troubleshooting 44 The System Will Not Boot 1. Ensure the NetServer is plugged into to the correct power source. NOTE The HP NetServer

Pagina 55 - General System Problems

Chapter 5 Troubleshooting 45 NOTE This information assumes that the customer is booting MS-DOS (DiagTools is based on MS-DOS). If the customer is n

Pagina 56

Chapter 5 Troubleshooting 46 • First make sure that the system is configured properly. Most system problems are the result of incorrect system and S

Pagina 57

Chapter 5 Troubleshooting 47 2. Rename any BAT file used by the customer to start the application. 3. Retest the hardware and software. If both

Pagina 58 - DIMM Memory Problems

Chapter 5 Troubleshooting 48 9. Power down the HP NetServer and remove the cover. 10. Reset Switch 7 from On (closed) to Off (open) in the conf

Pagina 59 - CD-ROM Problems

Chapter 5 Troubleshooting 49 Password Problems Use this topic to help with any Password Problems you might be having. If you forget the User password

Pagina 60

Chapter 5 Troubleshooting 50 3. Ensure the NetServer is turned on. The front panel power-on LED and the power supply LED should be green and the f

Pagina 61 - Keyboard and Mouse Problems

Chapter 5 Troubleshooting 51 6. Boot the HP NetServer Navigator CD-ROM and run the Error Logging utility. If the system powers up and immediately

Pagina 62 - Network Interface Problems

Chapter 5 Troubleshooting 52 Replace the defective DIMM. D. If you have rebooted the system with a known good DIMM and the error does not go away,

Pagina 63 - Power Problems

Chapter 5 Troubleshooting 53 • ECC (Error Checking and Correction) Single-Bit Errors. These errors may be detected in POST as in run-time. Appropria

Pagina 65 - Printer/Datacomm Problems

Chapter 5 Troubleshooting 54 2. Insert a pointed object, such as a paper clip, into the emergency eject hole and push in about 1.5 inches (40 mm).

Pagina 66 - SCSI Subsystem Problems

Chapter 5 Troubleshooting 55 1. ATAPI CD-ROM Drive2. Removable Device3. Hard Drive4. Enter Setup Utility 3. Use the keyboard's arrow keys to s

Pagina 67

Chapter 5 Troubleshooting 56 CAUTION The Keyboard and Mouse ports are both PS/2 ports, but are not interchangeable. If you plug the keyboard into t

Pagina 68

Chapter 5 Troubleshooting 57 • Check the LEDs on the adapter at the back of the computer. • Ensure you're using the correct drivers. • Ensure

Pagina 69 - PCI Board Problems

Chapter 5 Troubleshooting 58 StatusLEDCaptive ScrewFanVentCaptiveScrewACInletReleaseHandle LC 2000 Power Supply Rear View Power Supply Module LED Sta

Pagina 70 - Video/Monitor Problems

Chapter 5 Troubleshooting 59 b. Reset the circuit breaker after reconfiguring the devices. At some installation sites, if the circuit breakers are

Pagina 71

Chapter 5 Troubleshooting 60 SCSI Subsystem Problems An external SCSI subsystem does not work at installation If your external SCSI subsystem does no

Pagina 72

Chapter 5 Troubleshooting 61 11. If a second hard disk drive is connected to the SCSI bus cable, check it for proper SCSI ID selection, SCSI cable

Pagina 73 - 6 Replacing Parts

Chapter 5 Troubleshooting 62 B. Select the either the internal or external SCSI controller. The internal SCSI channel is usually port 2000. Press

Pagina 74 - Replacing the System Battery

Chapter 5 Troubleshooting 63 16. Check that all SCSI devices LVD (low votage differential) SCSI and that no SE (single-ended) SCSI devices have be

Pagina 75 - Replacing the Bezel

1 1 General Information Notice to Service Technicians This is the service document for the HP NetServer LC2000 server. You also need to access the H

Pagina 76 - Removing the Rack Bezel

Chapter 5 Troubleshooting 64 PCI board fails intermittently • Verify the PCI card is properly seated. Clean the card-edge contacts. • Check for ade

Pagina 77 - Replacing the CD ROM Drive

Chapter 5 Troubleshooting 65 B. Refer to the manual provided with the screen saver utility. 8. Verify the memory modules are correctly seated i

Pagina 78 - Replacing the Control Panel

Chapter 5 Troubleshooting 66 B. Verify the display power cable is connected to an AC power outlet and the video cable is connected to the NetServe

Pagina 79 - Chapter 6 Replacing Parts

67 6 Replacing Parts Safety Information Use this topic to determine what safety precautions should be followed when servicing the HP NetServer. Follo

Pagina 80 - Replacing DIMMs

Chapter 6 Replacing Parts 68 5. Turn the NetServer onto its top. 6. Pull up on the two tabs. NOTE The front bezel may remain in place while th

Pagina 81 - DIMM Replacement

Chapter 6 Replacing Parts 69 3. Press the power switch on the HP NetServer's control panel when prompted by the operating system. 4. Disco

Pagina 82 - Retaining

Chapter 6 Replacing Parts 70 You must remove the bezel to remove the other covers from the HP NetServer or to access front-end components. 1. To r

Pagina 83 - Thumbscrew

Chapter 6 Replacing Parts 71 Press down onBlue Tab to Release BezelSlide Securing Screws (2)Blue SlideRelease Button (2)Hinge Pins (3) Removing the H

Pagina 84 - Replacing the Duplex Card

Chapter 6 Replacing Parts 72 4. Disconnect the power cables. WARNING The power supplies will continue to provide standby current to the NetServer

Pagina 85

Chapter 6 Replacing Parts 73 3. Press the power switch on the HP NetServer's control panel when prompted by the operating system. 4. Disco

Pagina 86

Chapter 1 General Information 2 Removing the HP NetServer's Bezel CAUTION To prevent damage to the covers, support the cover as you remove it

Pagina 87 - Replacing the Fan Assembly

Chapter 6 Replacing Parts 74 Replacing DIMMs NOTE If a DIMM is not recognized by the NetServer during boot, consider reseating it in the slot before

Pagina 88

Chapter 6 Replacing Parts 75 CAUTION Wear a wrist strap and use a static-dissipating work surface connected to the chassis when handling components.

Pagina 89 - chassis

Chapter 6 Replacing Parts 76 . 2. Remove the HP DIMM from its container, handling the module by its edges. 3. Align the notches on the DIMM with

Pagina 90

Chapter 6 Replacing Parts 77 5. Gain access to the HP NetServer by referring to Replacing the Bezel and Replacing the Covers. 6. Remove all dri

Pagina 91 - Replacing Hot Swap Drives

Chapter 6 Replacing Parts 78 Screws Holding Hot Swap Cage to Chassis 10. Slide the hot swap cage forward and out of the chassis. Replacing the Ho

Pagina 92 - Drive Spacer

Chapter 6 Replacing Parts 79 WARNING The power supplies will continue to provide standby current to the NetServer until the power cable is disconnec

Pagina 93

Chapter 6 Replacing Parts 80 Duplex BoardDuplex Board Cable Duplex Card Cable Removed 8. Remove the Duplex card. Duplex Card Removal/ Replacement

Pagina 94 - Replacing PCI-Latch Hardware

Chapter 6 Replacing Parts 81 Replacing the Fan Assembly Use this topic to replace the Fan Module or the entire Fan Assembly. The three fans in the HP

Pagina 95 - Replacing a Power Supply

Chapter 6 Replacing Parts 82 Thumbscrewon back of fan module Fan Module Removal NOTE It may be necessary to remove some of the PCI boards (full leng

Pagina 96 - (Power Supply #2)

Chapter 6 Replacing Parts 83 Captive Screwsholding fan tray to chassis Removing the Fan Tray 10. Lift it up and out of the system. 11. To rep

Pagina 97 - Power Supply Replacement

Chapter 1 General Information 3 12. To replace the left side cover, position the cover’s tabs next to the respective holes along the outer edge on

Pagina 98

Chapter 6 Replacing Parts 84 5. Gain access to the HP NetServer by referring to Replacing the Bezel and Replacing the Covers. CAUTION Wear a wris

Pagina 99

Chapter 6 Replacing Parts 85 Replacing Hot Swap Drives The Hot Swap drive cage can support a variety of hard-drive configurations. When drive LEDs in

Pagina 100 - Captive Screw Locations

Chapter 6 Replacing Parts 86 CAUTION Use caution when handling the drive to prevent damage to the fragile light pipes. 3. Once the latch is open,

Pagina 101 - Replacing the System Board

Chapter 6 Replacing Parts 87 2. With the drive ejector handle open, slide the drive into the Hot Swap assembly. Inserting the Drive 3. Once it

Pagina 102 - Processor Cage

Chapter 6 Replacing Parts 88 CAUTION Protect the drive from static electricity by leaving it in its anti-static bag until you are ready to install i

Pagina 103 - Replacing VRMs

Chapter 6 Replacing Parts 89 The plastic latch (6), which holds the PCI board in place, is hinge mounted on a molded plastic frame and the plastic fr

Pagina 104 - Rotate latches out

Chapter 6 Replacing Parts 90 Use this topic to remove and replace a power supply in the HP NetServer. Only one power supply (350 Watt) is required fo

Pagina 105

Chapter 6 Replacing Parts 91 StatusLEDCaptive ScrewFanVentCaptiveScrewACInletReleaseHandleStrainrelief LC 2000 Power Supply Rear Panel 3. Grasp th

Pagina 106

Chapter 6 Replacing Parts 92 3. Insert the power cord into the power inlet. 4. Verify the status LED goes On (green) when the NetServer is powe

Pagina 107

Chapter 6 Replacing Parts 93 FlexibleDiskDriveSCSI ASCSI BIDECD-ROM123456Slots P1-4Slots P5-6Control Panel ConnnectorConfigurationSwitchTopTools I C

Comentarios a estos manuales