Red Hat ENTERPRISE LINUX 4.5.0 - Guía de usuario Pagina 113

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 117
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 112
113
127.0.0.1 server1 localhost.localdomain localhost
10.1.2.2 server2
[Example 3] The transmission former IP address of the trap is 10.1.2.1.
127.0.0.1 localhost.localdomain localhost
10.1.2.1 server1
10.1.2.2 server2
Teach the message which NEC ESMPRO Agent records in a syslog.
Refer to "Report Message" of SNMP Trap List for the message which NEC ESMPRO Agent records in a
syslog.
<Example>
Sep 13 07:46:26 test-host ESMamvmain: SRC:ESMCommonService, ID:80000065, MSG:The
temperature has been exceeded the upper threshold (Warning). Sensor Number: 3
Location: system board 1 Temperature: 42 degrees C Threshold: 42 degrees C
The correspondence of the message mentioned above and SNMP Trap List is as follows.
SRC:ESMCommonService
ID:80000065
MSG:The temperature has.
= Source Name
= Event ID
= Report Message
Teach facility and the priority of the message which NEC ESMPRO Agent records in
a syslog
The priority is different from the facility of the message which NEC ESMPRO Agent records in a syslog by a
version.
NEC ESMPRO Agent Ver.4.2 or later
Information facility : user
priority : info
Warning facility : user
priority : warning
Error facility : user
priority : err
Less than NEC ESMPRO Agent Ver.4.1
Information facility : user
priority : info
Warning facility : user
priority : info
Error facility : user
priority : info
Teach SNMP version that NEC ESMPRO Agent supports.
SNMP version that NEC ESMPRO Agent supports is only SNMP v1. By the setting of snmpd.conf, the
following wavy lines correspond.
[Extract of snmpd.conf]
# groupName securityModel securityName
group notConfigGroup v1 notConfigUser
group notConfigGroup v2c notConfigUser
Teach a method that sort a source name and Event ID in ascending order and
descending order, and to displa y.
The turn of the source name and the turn of Event ID use the readdir() function that is the system call of the
kernel. Because it is repaid in inode numerical orders not file name order from readdir() function, and cannot
display order in turn.
* inode number ... It is one of the management information of the file system and expresses ID number of the
Vista de pagina 112
1 2 ... 108 109 110 111 112 113 114 115 116 117

Comentarios a estos manuales

Sin comentarios