Requirements: All OS.
Description: The transmission speed of the network might not be correctly displayed on [Constitution
Information] - [Network], according to the specification of hardware and the specification of driver.
Solution: It is influence only for display, and there is not the influence for a monitor function of NEC ESMPRO
Agent.
Interface type of the network.
Requirements: All OS.
Description: The type of the network interface supported by NEC ESMPRO Manager is only Ethernet and
Loopback. Other types of the network interface might not be correctly displayed.
MAC information of Niantic tip (LOM/10G-KR Mezz).
Requirements: All OS.
Description: [Constitution Information]-[Network]-[(interface name)]-[MAC] acquires from EtherLike-MIB
which net-snmp makes and displays it. Because a part of MAC information does not exist in EtherLike-MIB
mentioned above without handling of to acquire some information MAC information being implemented for the
driver of Niantic tip, MAC information displaying with DataViewer of NEC ESMPRO Manager is not sometimes
right.
Solution: It is influence only for display, and there is not the influence for a monitor function of NEC ESMPRO
Agent.
Physical memory consumption.
Requirements: All OS.
Description: The physics memory consumption displaying with [Constitution Information] - [System] -
[Memory] calculates contents of "/proc/meminfo" as follows.
Physics memory consumption = MemTotal - MemFree
This value includes Buffers and Cached. Therefore, a high value might be indicated by the situation of the
system.
There is time when NEC ESMPRO Manager cannot display the constitution of the
server.
Requirements: Less than NEC ESMPRO Agent Ver.4.5.0-1.
Improvement: NEC ESMPRO Agent Ver.4.5.0-1 or later.
Description: When you removed a device (fan or Power supply Unit, etc) corresponding to the hot swap in
the state that started NEC ESMPRO Manager, It cannot sometimes display constitution information definitely.
Solution: Update processing in improved NEC ESMPRO Agent Ver.4.5.0-1 or later, or after having waited for
around 5 minutes when you changed the constitution of the system, click "Constitution" tab and reload
constitution information.
There is time when it is displayed if the connector shape of the serial port is
unknown.
Requirements: SMBIOS Type8 Port Connector Information is a device of non-support.
Description: The connector shape of a serial port displaying with [Constitution Information] - [I/O Device]
displays information of SMBIOS Type8 Port Connector Information for the cause. If the connector shape of
the serial port is unidentified, SMBIOS Type8 Port Connector Information displays it in a device of non-support.
About support having SMBIOS Type8 or not, confirm whether the following information (type 8) is displayed