21
Sample Interval(s)
Specify the sampling interval. Range is 1 to 3600 seconds. Default value is 60 seconds.
[Default]
When you press [Default], the sample interval will be set to default value.
Filesystem
Select a file system to change threshold and/or monitoring mode, using "UP/DOWN" arrow keys.
Disable Threshold
When checked, the free space of the file system is not monitored. Set using space key.
Enable Threshold (The amount of free bytes)
When checked, the free space of the file system is monitored. Set using space key.
The threshold can only be set when checked. This field is checked by default.
Threshold
Set the warning and fatal thresholds.
It is necessary to satisfy the following big things and small things relations.
All capacity > Warning > Fatal > 0
Default values of warning and fatal thresholds are as follows.
[Default]
When you press [Default], the thresholds will be set to default value.
1 percent of the capacity
10 percent of the capacity