93
Description: The sensor of the temperature / voltage / fan which does not have information such as a state, a
current value, number of revolutions, the threshold by a model exists. Therefore it may be displayed as follows
when you referred to an applicable sensor in NEC ESMPRO Manager.
- In [Information of server state/constitution] of NEC ESMPRO Manager, a state is displayed with
"unknown".
- In [Information of server state/constitution] of NEC ESMPRO Manager, current value or number of
revolutions is not displayed or it is displayed with "unknown".
Solution: It is influence only for display, and there is not the influence for a monitor function of NEC ESMPRO
Agent.
A memory bank becomes the nonimplement (gray indicati on).
Requirements: The number of DIMM implementing is the server of the odd number.
Improvement: NEC ESMPRO Agent Ver.4.5.4-1 or later.
Description: The number of DIMM implementing is odd server, and [Constitution Information] - [Hardware] -
[Memory Bank] is displayed with nonimplement (gray indication), but does not have any problem if
implementation position same as implemented memory becomes really normal. When warning / fatal of DIMM
occurs, a memory bank becomes the yellow (warning) / red (fatal) and can detect obstacle.
Solution: Update processing in improved NEC ESMPRO Agent Ver.4.5.4-1 or later, or it is influence only for
display, and there is not the influence for a monitor function of NEC ESMPRO Agent.
There is time when it is displayed if file s ystem of ext4 is unknown.
Requirements: File system is ext4.
Description: If file system of the file system addition information is unclear, it is displayed with DataViewer of
NEC ESMPRO Manager. It supports file system ext4 than NEC ESMPRO Agent Ver.4.4.26-1, but the reason
is because DataViewer of NEC ESMPRO Manager does not support indication.
Solution: It is influence only for display, and there is not the influence for a monitor function of NEC ESMPRO
Agent.
Use to NEC ESMPRO Manager Ver.5.40 or later (for Windows).
There is time when storage is as warning after hard disk drive exchange.
Requirements: NEC ESMPRO Agent all versions.
Description: When you performed exchange and the addition of the hard disk drive, there is time when
indication is not displayed definitely [Constitution Information] - [Storage].
Solution: Click "Constitution" tab and reload constitution information. In addition, when you do exchange and
the addition of the hard disk drive, with reference to chapter 2 "5. Storage Monitoring", reset the information of
exchange or addition the hard disk drive which is targeted for monitoring.
There is time to display plural [Constitution Information] - [Storage] - [CD-ROM]
with a model equipped with a DVD combo drive.
Requirements: System kernel version 2.4 or later of a model equipped with a DVD combo drive.
Description: This phenomenon occurs so that ide-scsi emulation is necessary when you use the note
function of a writable optical drive of IDE connection in the 2.4 system kernel so that it is recognized by both
IDE connection and SCSI connection.
Solution: Only under the influence that indication becomes the plural number, there is not the influence for a
function of NEC ESMPRO Agent.
The transfer speed of the network is not sometimes displayed definitely.