reported at the time of OS start by the timing when the phenomenon of the report object occurs.
Solution: Confirm the message which is displayed after the above for 5 minutes to AlertViewer after OS
started.
When report means of SNMP is not effective, there is the thing that SNMP report is
transmitted.
Requirements: All OS.
Description: When the phenomenon of the report object occurred when there is not ready for the report at the
time of OS start, it does re-try processing. When trap report ahead IP was set by a re-timing working to try it to
handle a report regardless of report means (ON/OFF) of SNMP, report means of SNMP reports the re-try
processing even at the time of OFF.
Solution: When you do not want to let you report it, set it after passing after OS start more than 5 minutes.
There is time when a message output or displayed in syslog for the run time of the
obstacle information collection tool (collectsa.sh).
Requirements:
output message 1, 2: net-snmp-5.3.1-24.el5
output message 3 : net-snmp-5.5-44.el6 (Red Hat Enterprise Linux 6.4)
Description: When you run the obstacle information collection tool (collectsa.sh), following message is
displayed in syslog, but these messages do not affect NEC ESMPRO Agent.
output message 1 :
process 'sysctl' is using deprecated sysctl (syscall) net.ipv6.neigh.vswif0.base_reachable_time;
Use net.ipv6.neigh.vswif0.base_reachable_time_ms instead.
output message 2 :
process 'cp' is using deprecated sysctl (syscall) net.ipv6.neigh.vswif0.base_reachable_time;
Use net.ipv6.neigh.vswif0.base_reachable_time_ms instead.
output message 3 :
kernel: netlink: 12 bytes leftover after parsing attributes.
Solution: There is not the influence for a monitor function of NEC ESMPRO Agent.
About a rack name change of EM card deployment device .
Requirements: EM card deployment device.
Description: In the case of CPU blade which installed in a blade storing unit of EM card deployment of
Control Panel (ESMagntconf) of NEC ESMPRO Agent cannot change "Rack Name" from [General Properties]
screen.
Solution: With the function of EM cards such as Web console functions, set it. About the setting procedure,
refer to blade storing unit Users Guide.
A report with WebSAM AlertManager needs registry registration to cooperate.
Requirements: NEC ESMPRO Agent all versions.
Description: When you let the event that you added by the setting of Syslog Monitoring Event cooperate with
NEC ESMPRO Manager in WebSAM AlertManager, register the following registry with the machine which
installed NEC ESMPRO Manager.
Solution: Set the following keys, a name and data with a Registry editor.
It is the name of the alert type that "xxxx" sets newly.
--------------------------------------------------------------------------
[HKEY_LOCAL_MACHINE¥SOFTWARE¥NEC¥NVBASE¥AlertViewer¥AlertType¥xxxx]